RU | EN
Download brochure


Barnaul
Very Urgent Matter!

Please contact our Duty Manager in case of urgent situations, equipment failure or other pressing matters. You can use the following ways:

1. Direct call:

+7 952 009 05 30

2. Skype call: russol24
3. Direct SMS:

General search
Equipment
choose the category
  •  Fans 
  •  Boilers 
  • Valves
  •  Chains 

Choose the boiler type
Boilers search
Select boiler
Capacity: t/h
Output pressure: MPa
Output temperature: С о
Permissible variation ?: %
Boilers search
Select boiler
Capacity: MW
Output pressure: MPa
Permissible variation ?: %
Valves search
Select valve
DN: mm
Pressure: MPa
Temperature: оС
Permissible variation ?: %
Industrial fans questionnaire
X Please send us your request via this form or via email at: ✉ info@russol.org
General information
① Fan type: FD Fan
ID Fan
② Subtype:
③ Climatic modification ?:
④ Scroll layout ?: ° - °
⑤ Rotation direction ?: Right-hand
Left-hand
⑥ Quantity: pcs.
⑦ Delivery date:
Technical data
① Capacity: ths. m3/h
② Handled medium temperature: °C
③ Total pressure:
④ Atmospheric pressure: ?:
⑤ Required efficiency:
⑥ Capacity regulation: ?: Yes
No
Electric motor
① Type:

Asynchronous squirrel cage
Asynchronous with phase-wound rotor
Synchronous
② Climatic modification ?:
③ Rate speed: rpm
④ IP ?: IP
⑤ Supply-line voltage: V
⑥ Frequency: Hz
Handled medium ?
① Density kg/Nm3
② Dustiness: g/Nm3
③ Agressive agents content: %
④ Sticking tendency: ?
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*
* - fields are to be filled.
Additional comments
Boiler questionnaire
X Please send us your request via this form or via email at: ✉ info@russol.org
General information
① Boiler type: Steam
Hot-water
② Application: Heating
Hot-water supply
Process needs
Power generation
③ Fuel ?: 1:
2:
④ Quantity: шт.
⑤ Delivery date:
Technical data
① Steam capacity: t/h
② Output pressure:
③ Output temperature: °C
④ Supply water temperature: °C
① Capacity:
② Operating output pressure:
③ Water temperature graph: °C
Auxiliaries
Combustion chamber:
Steam superheater Economizer
Air heater Coal pulverization
Mill fan FD Dan
ID Fan Ash catcher
Chimney Ash and slag removal
CPCS Phosphatizing
Water treatment Soot blowers
Fuel 1
① Grade:
② Calorific value: kcal/kg
③ Lump size: mm
④ Humidity: %
⑤ Ash: %
⑥ Ultimate composition: % - Carbon (C)
% - Hydrogen (H)
% - Oxygen (O)
% - Nitrogen (N)
% - Sulfur(S)
① Calorific value: ?: kcal/m3
② Gas cubic meter weight: kg/m3
③ Gas temperature: °С
④ Ultimate composition: % - Carbon monoxide (СО)
% - Carbon dioxide (СО2)
% - Hydrogen (H2)
% - Oxygen (O2)
% - Nitrogen (N2)
% - Methane (CH4)
% - Heavy hydrocarbon (СmHm)
% - Hydrogen sulphide (H2S)
① Calorific value: kcal/kg
② Ash: %
③ Lump size: mm
④ Humidity: %
① Fuel grade:
② Calorific value: kcal/kg
③ Flash point: °С
① Calorific value: kcal/kg
② Ash: %
③ Tap density: kg/m3
④ Humidity: %
Fuel 2
① Grade:
② Calorific value: kcal/kg
③ Lump size: mm
④ Humidity: %
⑤ Ash: %
⑥ Ultimate composition: % - Carbon (C)
% - Hydrogen (H)
% - Oxygen (O)
% - Nitrogen (N)
% - Sulfur(S)
① Calorific value: ?: kcal/m3
② Gas cubic meter weight: kg/m3
③ Gas temperature: °С
④ Ultimate composition: % - Carbon monoxide (СО)
% - Carbon dioxide (СО2)
% - Hydrogen (H2)
% - Oxygen (O2)
% - Nitrogen (N2)
% - Methane (CH4)
% - Heavy hydrocarbon (СmHm)
% - Hydrogen sulphide (H2S)
① Calorific value: kcal/kg
② Ash: %
③ Lump size: mm
④ Humidity: %
① Fuel grade:
② Calorific value: kcal/kg
③ Flash point: °С
① Calorific value: kcal/kg
② Ash: %
③ Tap density: kg/m3
④ Humidity: %
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*
⑥ Comments:
* - fields are to be filled.
Valve questionnaire
X Please send us your request via this form or via email at: ✉ info@russol.org
General information
① Type:
② Subtype:
② Subtype:
② Subtype:
③ Operating medium: Steam Water
④ DN:Input:   mm
Output: mm
⑤ Climatic modification ?:
⑥ Leakage class ?:
⑦ Body material:
⑧ Quantity: pcs.
⑨ Date of delivery:
Technical data
① Fluid temperature: °С
② Input pressure: MPa
③ Output pressure: MPa
② PN: MPa
③ Operating pressure: MPa
④ Max. flow rate under min. pressure differential, Gмах: t/h
⑤ Max. flow rate Gмах: t/h
⑥ Min. pressure differential unde max. flow rate: MPa
⑦ Max. pressure differential under min flow rate: MPa
⑧ On-stream time under max. pressure differential: h/year
④ Opening pressure: MPa
⑤ Reverse-seat pressure: MPa
① Main steam capacity: t/h
② Desuperheated steam capacity: t/h
③ Main steam pressure MPa
④ Main steam temperature °С
⑤ Desuperheated steam pressure MPa
⑥ Desuperheated steam temperature °С
⑦ Cooling water pressure MPa
⑧ Cooling water temperature °С
Привод
① Control type: Manual
Actuator
② Actuator producer: Russian
Other
③ Total opening (closing) time: s
Pipeline
① PipelineOuter diameter:  mm
Wall thickness:   mm
② Type of connection: Welded neck
Flanges
③ Additional requirements:
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*
⑥ Comments:
* - fields are to be filled.

1203-150_200-0-02


General information
TypeMain safety-valves
Subtype:High parameters valves
Operating medium: steam
Body material:15Х1М1ФЛ
Description
Safety-valves are designed to prevent equipment damage under extreme pressure level by means of automatic vent of liquid, gaseous, vaporized medium excesses from vessels and systems with overpressure.

We provide a full range of customer service including full warranty, 24/7 consultation and support, valuable insights into the ideal technical solutions in accordance with your requirements and expectations. At your desire we will be glad to supervise or execute the installation and commissioning process. Thanks to strict control over manufacturing process each equipment unit is inspected and recorded so the aftermarket support and spare parts delivery are notable for promptness and full interchangeability. To prolong the life-time of your equipment we are always ready to render on-site services from scheduled maintenance to troubleshooting, equipment inspection and emergency & repair works. All-time we keep our customers informed concerning possible improvements, up-to-date solutions and technical developments which can help to upgrade your equipment and enhance efficiency.

Technical data
Diameter, DN:150/200mm
Pressure, PN:7.75MPa
Maximum steam rate:120t/h
Temperature:521
Minimum passage area:68.7 cm2
Flow coefficient:0.5
Operating stroke:25 mm
Dimensions
D: - mm
D1: - mm
D2: - mm
L: 280 mm
H: 900 mm
H1: 350 mm
A: - mm
B: - mm
C: - mm
N: - mm
DM: - mm
DP1: 163 mm
DH1: 225 mm
DP2: 188 mm
DH2: 225 mm
Weight: 345 kg
Drawing
This equipment can be searched by the following tags: 1203-150_200-0-02, Main safety-valves, High parameters valves, 1203-150_200-0-02 of Main safety-valves, High parameters valves 1203-150_200-0-02 of Main safety-valves ,High parameters valves Main safety-valves, , DN 150/200, DN 150/200 Valve, Valve, 1203-150_200-0-02, На высокие параметры, Главные предохранительные клапаны, 1203-150_200-0-02 valve.
Request for spares of 1203-150_200-0-02
X
Please send us your request via this form or via email at: ✉ info@russol.org
Spare parts
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*

* - fields are to be filled.
Price request for 1203-150_200-0-02
X
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Required quantity:
⑥ Place of delivery:
⑦ Delivery date:
⑧ Email:*
Additional comments

* - fields are to be filled.