Choose the boiler type
Boilers search
Select boiler
Capacity: t/h
Output pressure: MPa
Output temperature: С о
Permissible variation ?: %
Boilers search
Select boiler
Capacity: MW
Output pressure: MPa
Permissible variation ?: %
Valves search
Select valve
DN: mm
Pressure: MPa
Temperature: оС
Permissible variation ?: %
Industrial fans questionnaire
X Please send us your request via this form or via email at: ✉ info@russol.org
General information
① Fan type: FD Fan
ID Fan
② Subtype:
③ Climatic modification ?:
④ Scroll layout ?: ° - °
⑤ Rotation direction ?: Right-hand
Left-hand
⑥ Quantity: pcs.
⑦ Delivery date:
Technical data
① Capacity: ths. m3/h
② Handled medium temperature: °C
③ Total pressure:
④ Atmospheric pressure: ?:
⑤ Required efficiency:
⑥ Capacity regulation: ?: Yes
No
Electric motor
① Type:

Asynchronous squirrel cage
Asynchronous with phase-wound rotor
Synchronous
② Climatic modification ?:
③ Rate speed: rpm
④ IP ?: IP
⑤ Supply-line voltage: V
⑥ Frequency: Hz
Handled medium ?
① Density kg/Nm3
② Dustiness: g/Nm3
③ Agressive agents content: %
④ Sticking tendency: ?
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*
* - fields are to be filled.
Additional comments
Boiler questionnaire
X Please send us your request via this form or via email at: ✉ info@russol.org
General information
① Boiler type: Steam
Hot-water
② Application: Heating
Hot-water supply
Process needs
Power generation
③ Fuel ?: 1:
2:
④ Quantity: шт.
⑤ Delivery date:
Technical data
① Steam capacity: t/h
② Output pressure:
③ Output temperature: °C
④ Supply water temperature: °C
① Capacity:
② Operating output pressure:
③ Water temperature graph: °C
Auxiliaries
Combustion chamber:
Steam superheater Economizer
Air heater Coal pulverization
Mill fan FD Dan
ID Fan Ash catcher
Chimney Ash and slag removal
CPCS Phosphatizing
Water treatment Soot blowers
Fuel 1
① Grade:
② Calorific value: kcal/kg
③ Lump size: mm
④ Humidity: %
⑤ Ash: %
⑥ Ultimate composition: % - Carbon (C)
% - Hydrogen (H)
% - Oxygen (O)
% - Nitrogen (N)
% - Sulfur(S)
① Calorific value: ?: kcal/m3
② Gas cubic meter weight: kg/m3
③ Gas temperature: °С
④ Ultimate composition: % - Carbon monoxide (СО)
% - Carbon dioxide (СО2)
% - Hydrogen (H2)
% - Oxygen (O2)
% - Nitrogen (N2)
% - Methane (CH4)
% - Heavy hydrocarbon (СmHm)
% - Hydrogen sulphide (H2S)
① Calorific value: kcal/kg
② Ash: %
③ Lump size: mm
④ Humidity: %
① Fuel grade:
② Calorific value: kcal/kg
③ Flash point: °С
① Calorific value: kcal/kg
② Ash: %
③ Tap density: kg/m3
④ Humidity: %
Fuel 2
① Grade:
② Calorific value: kcal/kg
③ Lump size: mm
④ Humidity: %
⑤ Ash: %
⑥ Ultimate composition: % - Carbon (C)
% - Hydrogen (H)
% - Oxygen (O)
% - Nitrogen (N)
% - Sulfur(S)
① Calorific value: ?: kcal/m3
② Gas cubic meter weight: kg/m3
③ Gas temperature: °С
④ Ultimate composition: % - Carbon monoxide (СО)
% - Carbon dioxide (СО2)
% - Hydrogen (H2)
% - Oxygen (O2)
% - Nitrogen (N2)
% - Methane (CH4)
% - Heavy hydrocarbon (СmHm)
% - Hydrogen sulphide (H2S)
① Calorific value: kcal/kg
② Ash: %
③ Lump size: mm
④ Humidity: %
① Fuel grade:
② Calorific value: kcal/kg
③ Flash point: °С
① Calorific value: kcal/kg
② Ash: %
③ Tap density: kg/m3
④ Humidity: %
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*
⑥ Comments:
* - fields are to be filled.
Valve questionnaire
X Please send us your request via this form or via email at: ✉ info@russol.org
General information
① Type:
② Subtype:
② Subtype:
② Subtype:
③ Operating medium: Steam Water
④ DN:Input:   mm
Output: mm
⑤ Climatic modification ?:
⑥ Leakage class ?:
⑦ Body material:
⑧ Quantity: pcs.
⑨ Date of delivery:
Technical data
① Fluid temperature: °С
② Input pressure: MPa
③ Output pressure: MPa
② PN: MPa
③ Operating pressure: MPa
④ Max. flow rate under min. pressure differential, Gмах: t/h
⑤ Max. flow rate Gмах: t/h
⑥ Min. pressure differential unde max. flow rate: MPa
⑦ Max. pressure differential under min flow rate: MPa
⑧ On-stream time under max. pressure differential: h/year
④ Opening pressure: MPa
⑤ Reverse-seat pressure: MPa
① Main steam capacity: t/h
② Desuperheated steam capacity: t/h
③ Main steam pressure MPa
④ Main steam temperature °С
⑤ Desuperheated steam pressure MPa
⑥ Desuperheated steam temperature °С
⑦ Cooling water pressure MPa
⑧ Cooling water temperature °С
Привод
① Control type: Manual
Actuator
② Actuator producer: Russian
Other
③ Total opening (closing) time: s
Pipeline
① PipelineOuter diameter:  mm
Wall thickness:   mm
② Type of connection: Welded neck
Flanges
③ Additional requirements:
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*
⑥ Comments:
* - fields are to be filled.

BKZ type (coal)


BKZ type (coal)
NameFuelCapacity,
t/h
Output pressure,
MPa (kgs/cm2)
Output temperature,
°С
Efficiency,
%
BKZ 690-13,8bituminous coal690.013.8 (138) 54091,4
BKZ 670-140-3brown coal670.013.8 (138) 54589
BKZ 670-140-4brown coal670.013.8 (138) 54088,7
BKZ 500-140-1brown coal500.013.8 (138) 56092
BKZ 500-13,8-4Sbituminous coal500.013.8 (138) 56092,5
BKZ 500-13,8 BSH-1Sbituminous coal500.013.8 (138) 56091,5
BKZ 500-13,8 TSKS-1bituminous / brown coal500.013.8 (138) 56091
BKZ 420-140-5bituminous coal420.013.8 (138) 56091,4
BKZ 420-140-7brown coal420.013.8 (138) 56091,8
BKZ 420-140-15Sbituminous coal420.013.8 (138) 56091,5
BKZ 360-13,8-1Sbituminous / brown coal360.013.8 (138) 56090,5
BKZ 320-140/25anthracite320.013.8 (138) 54586,5
BKZ 220-100-9bituminous / brown coal220.09.8 (98) 54091,7
BKZ 220-100-11S,12Sbrown coal, lignite220.09.8 (98) 54087,5
BKZ 210-140-9bituminous / brown coal210.013.8 (138) 56091,8
BKZ 210-140-11Santhracite210.013.8 (138) 56084,5
BKZ 220-9,8-13bituminous coal220.09.8 (98) 54092,3
BKZ 200-100 Flignite200.09.8 (98) 54087,2
BKZ 160-1,4-1bituminous / brown coal160.01.4 (14) 250-38090,9
BKZ 160-1,6 TSKS-2high-ash bituminous coal160.01.6 (16) 30091
BKZ 90-3,9high-ash bituminous coal90.03.9 (39) 44090,5
BKZ 65-3,9bituminous coal65.03.9 (39) 44089,5
Didn't find the required equipment? Please fill in the questionnaire and our designers will elaborate your request in the soonest possible time. Thank you!
Boiler questionnaire
X Please send us your request via this form or via email at: ✉ info@russol.org
General information
① Boiler type: Steam
Hot-water
② Application: Heating
Hot-water supply
Process needs
Power generation
③ Fuel ?: 1:
2:
④ Quantity: шт.
⑤ Delivery date:
Technical data
① Steam capacity: t/h
② Output pressure:
③ Output temperature: °C
④ Supply water temperature: °C
① Capacity:
② Operating output pressure:
③ Water temperature graph: °C
Auxiliaries
Combustion chamber:
Steam superheater Economizer
Air heater Coal pulverization
Mill fan FD Dan
ID Fan Ash catcher
Chimney Ash and slag removal
CPCS Phosphatizing
Water treatment Soot blowers
Fuel 1
① Grade:
② Calorific value: kcal/kg
③ Lump size: mm
④ Humidity: %
⑤ Ash: %
⑥ Ultimate composition: % - Carbon (C)
% - Hydrogen (H)
% - Oxygen (O)
% - Nitrogen (N)
% - Sulfur(S)
① Calorific value: ?: kcal/m3
② Gas cubic meter weight: kg/m3
③ Gas temperature: °С
④ Ultimate composition: % - Carbon monoxide (СО)
% - Carbon dioxide (СО2)
% - Hydrogen (H2)
% - Oxygen (O2)
% - Nitrogen (N2)
% - Methane (CH4)
% - Heavy hydrocarbon (СmHm)
% - Hydrogen sulphide (H2S)
① Calorific value: kcal/kg
② Ash: %
③ Lump size: mm
④ Humidity: %
① Fuel grade:
② Calorific value: kcal/kg
③ Flash point: °С
① Calorific value: kcal/kg
② Ash: %
③ Tap density: kg/m3
④ Humidity: %
Fuel 2
① Grade:
② Calorific value: kcal/kg
③ Lump size: mm
④ Humidity: %
⑤ Ash: %
⑥ Ultimate composition: % - Carbon (C)
% - Hydrogen (H)
% - Oxygen (O)
% - Nitrogen (N)
% - Sulfur(S)
① Calorific value: ?: kcal/m3
② Gas cubic meter weight: kg/m3
③ Gas temperature: °С
④ Ultimate composition: % - Carbon monoxide (СО)
% - Carbon dioxide (СО2)
% - Hydrogen (H2)
% - Oxygen (O2)
% - Nitrogen (N2)
% - Methane (CH4)
% - Heavy hydrocarbon (СmHm)
% - Hydrogen sulphide (H2S)
① Calorific value: kcal/kg
② Ash: %
③ Lump size: mm
④ Humidity: %
① Fuel grade:
② Calorific value: kcal/kg
③ Flash point: °С
① Calorific value: kcal/kg
② Ash: %
③ Tap density: kg/m3
④ Humidity: %
Contacts
① Company name:*
② Contact person:*
③ Telephone:*
④ Fax:
⑤ Email:*
⑥ Comments:
* - fields are to be filled.